BK PRECISION 5491B CALIBRATION and BK PRECISION 5491B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 5491B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   BK PRECISION 5491B   Description / Specification:   Spec Sheet 
BK PRECISION 5491B 4 3/4 Digit True RMS Bench Multimeter

The B&K Precision 5491B is a versatile and dependable 4 3/4 digit bench multimeter suitable for applications in education, service and repair, and manufacturing requiring basic and reliable measurements. Additionally, this instrument enhances your productivity with built-in math functions and USB connectivity, math operations include; Rel, Max/Min, dBm, dB, %, and Hold. The 5491B take typical multimeter measurements such as volts, ohms, and amps with great accuracy, stability, and basic VDC accuracy of 0.02%. This meter is also capable of measuring frequency, period, continuity, and performing diode tests. Readings can be taken at a maximum rate of 25 readings/sec with measurement rates selectable between slow, medium, and fast. Dual display to indicate two measurements simultaneously. Specifications. DC Voltage Range: 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V. AC Voltage Range: 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 750.0 V. DC Current Range: 5.0000 mA, 50.000 mA, 500.00 mA, 5.0000 A, 20.000 A. AC Current Range (True RMS, AC Coupling): 5.0000 mA, 50.000 mA, 500.00 mA, 5.0000 A, 20.000 A. Resistance Ranges: 500.00 ohm, 5.0000 k-ohm, 50.000 k-ohm, 500.00 k-ohm, 5.0000 M-ohm, 50.000 M-ohm. Continuity: 500 ohm. Diode Test current: 0.5 mA (Approx.). Frequency Range: 10 Hz, 100 Hz, 100 kHz, 1 MHz. Period Range: 10 µs, 10 ms, 100 ms. Display Resolution: 50,000 count.



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 5491B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your BK PRECISION 5491B CALIBRATION and/or BK PRECISION 5491B 4 3/4 Digit True RMS Bench Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: